Mocomtech CDM-QX Modem User Manual


 
CDM-Qx Satellite Modem Revision 5
Front Panel Operation MN/CDMQx.IOM
5–35
(ConfigGroupRedundancyMode)
Default is “Manual”. If “Auto” is selected, that means the back-up will automatically
take over once the designated prime is faulted, and vice-versa. If “Manual” is selected,
when the prime is faulted, the back up will not take over. Also, the user will have the
option to do force switching.
(ConfigGroupRedundancyModeManual)
If redundancy is configured (e.g. 1:1), force-backup menu will appear which will allow
the user to do force switching between back up and designated primary device.
5.6.1.5 (ConfigFrame) – FRAMING MODE
Framing requires a modulator/demodulator pair grouped into a modem (see
ConfigGroup).
Select Unframed, EDMAC, EDMAC-2, or D&I++ using the arrow keys, then
press ENT.
The sub-branches available are:
(ConfigFrameUnframed) - UNFRAMED
No framing is selected. No overhead is added, and the unit will be compatible with other
manufacturer’s equipment, when operating in a ‘standard’ configuration.
Framing Mode: Unframed EDMAC
EDMAC-2 D&I++ ( ,ENT)
Redundancy Mode:
Manual Auto ( ,ENT)
Redundancy Manual Mode:
Forced-Backup = Slot#1 (▲▼,ENT)