Mocomtech CDM-QX Modem User Manual


 
CDM-Qx Satellite Modem Revision 4
Remote Control MN/CDMQx.IOM
C-38
Parameter
Type
Command
(Instruction
Code and
qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response
to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to query
(Target to
Controller)
Software Image IMG= 1 byte, value of
1 or 2
Command or Query.
Current active software image, where:
1=Bulk Image #1 currently active
2=Bulk Image #2 currently active
IMG=
IMG?
IMG*
IMG#
IMG^
IMG? IMG=x
(see description of
arguments)
Serial Number
of Modulator or
Demodulator
N/A 9 bytes Query only
Used to query the modulator or demodulator card 9-digit
serial number. It returns its S/N in the form xxxxxxxxx
N/A SNO? SNO=xxxxxxxxx
(see description of
arguments)
Serial Number
of Base Unit
N/A 9 bytes Query only.
Used to query the 9-digit serial number of the Qx base
unit in the form: xxxxxxxxx
N/A SNM? SNM=xxxxxxxxx
(see description of
arguments)
Serial Number
of turbo card
N/A 9 bytes Query only.
Used to query the 9-digit serial number of the Turbo
Codec card.
N/A SNT? SNT=xxxxxxxxx
(see description of
arguments)
RX Frequency
Offset
N/A 6 bytes Query Only
Unit returns the value of the measured frequency offset of
the carrier being demodulated, in the form sxxx.x, where:
xxx.x=value (range from 0 to 200 kHz, 100 Hz resolution)
Returns +999.9 if the demodulator is unlocked
Example: RFO=+002.3 (2.3 kHz)
N/A RFO? RFO=sxxx.x
(see description of
arguments)
Buffer Fill State N/A 2 bytes Query only
Unit returns the value of the buffer fill state, between 1 to
99%
Returns 00 if demodulator is unlocked
Example: BFS=33 (33%)
N/A BFS? BFS=xx
(see description of
arguments)
Temperature of
Modulator
N/A 3 bytes Query only
It returns the value of the internal card temperature, in the
form of sxx (degrees C)
s=sign (+ or – character)
xx=value
Example: TMP=+26
N/A TMP? TMP=sxx
(see description of
arguments)