CDM-Qx Satellite Modem Revision 5
Front Panel Operation MN/CDMQx.IOM
5–56
In this example, the demodulator installed in slot #3 is faulted on Nov. 30, 2002 at
10:37:32 with log number 23.
(MonitorEvent-LogView) – VIEW STORED EVENTS
The user may scroll backwards or forwards through the entries in the event log, using the
STarrow keys. Pressing ENT or CLR will take the user back to the previous menu. The
event log can store up to 255 events. When a fault condition occurs, it is time-stamped and
put into the log. Similarly, when the fault condition clears, this is also recorded, as shown
below:
If the user selects Clear-All, the event log is cleared, and the user is taken directly back
to the previous menu. However, if there are faults present on the unit at this time, they
will be re-time-stamped, and new log entries will be generated.
IMPORTANT: Note that in accordance with international convention, the
date is shown in DAY-MONTH-YEAR format.
Log 023: 30/11/02 10:37:32
Fault - Demod Lock (3) (▲▼,ENT)
Log 024: 30/11/97 10:37:35
Clear - Demod Lock (3) (▲▼,ENT)
IMPORTANT