Delta Electronics ASDA-AB Network Card User Manual


 
Chapter 6 Control Modes of Operation|ASDA-AB Series
6-26 Revision January 2009
Low-pass filter
Please use parameter P2-25. The figure below shows the resonant open-loop gain.
Gain
Frequency
When the low-pass filter (parameter P2-25) is adjusted from 0 to high value, the value of Low-pass
frequency (BW) will become smaller (see the figure below). The resonant condition is improved and the
frequency response and phase margin will also decrease.
0dB
BW
Gain
Frequency
Notch Filter
Usually, if the users know the resonance frequency, we recommend the users can eliminate the
resonance conditions directly by using notch filter (parameter P2-23, P2-24). However, the range of
frequency setting is from 50 to 1000Hz only and the range of resonant attenuation is 0~32 dB only.
Therefore, if the resonant frequency is out of this range, we recommend the users to use low-pass filter
(parameter P2-25) to improve resonant condition.
Please refer to the following figures and explanation to know how to use notch filter and low-pass filter
to improve resonant condition.
Use Notch Filter to suppress resonance
0db
Notch Filter
Attenuation
Rate P2-24
Resonance
Frequency
.
Resonance
Point
Gain
Frequency
.
Gain
Frequency
Gain
Frequency
Low-pass
Frequency
Low-pass
Frequency
Resonance
Frequency
P2-23
Resonance
conditions
is suppressed
Resonance
Frequency