Delta Electronics ASDA-AB Network Card User Manual


 
Chapter 7 Servo Parameters|ASDA-AB Series
Revision January 2009 7-55
P2 - 10
DI1 Digital Input Terminal 1 (DI1) Communication Addr.: 020AH
Default: 101 Related Section:
Applicable Control Mode: ALL Table 7.A
Unit: N/A
Range: 0 ~ 147
Settings:
This parameter is used to determine the function and status of DI1.
not used
A
B
A: DI Function Settings: For the setting value of P2- 10 ~ P2-17, please refer to Table 7.A.
B: DI Enabled Status Settings:
0: Normally closed (contact b)
1: Normally open (contact a)
Please re-start the servo drive after parameters have been changed.
P2 - 11
DI2 Digital Input Terminal 2 (DI2) Communication Addr.: 020BH
Default: 104 Related Section:
Applicable Control Mode: ALL Table 7.A
Unit: N/A
Range: 0 ~ 147
Settings: See P2-10 for explanation.
P2 - 12
DI3 Digital Input Terminal 3 (DI3) Communication Addr.: 020CH
Default: 116 Related Section:
Applicable Control Mode: ALL Table 7.A
Unit: N/A
Range: 0 ~ 147
Settings: See P2-10 for explanation.