Delta Electronics ASDA-AB Network Card User Manual


 
Chapter 7 Servo Parameters|ASDA-AB Series
Revision January 2009 7-57
P2 - 18
DO1 Digital Output Terminal 1 (DO1) Communication Addr.: 0212H
Default: 101 Related Section:
Applicable Control Mode: ALL Table 7.B
Unit: N/A
Range: 0 ~ 112
Settings:
This parameter is used to determine the function and status of DO1.
not used
A
B
A: DO Function Settings: For the setting value of P2- 18 ~ P2-22, please refer to Table 7.A.
B: DO Enabled Status Settings:
0: Normally closed (contact b)
1: Normally open (contact a)
Please re-start the servo drive after parameters have been changed.
P2 - 19
DO2 Digital Output Terminal 2 (DO2) Communication Addr.: 0213H
Default: 103 Related Section:
Applicable Control Mode: ALL Table 7.B
Unit: N/A
Range: 0 ~ 112
Settings: See P2-18 for explanation.
P2 - 20
DO3 Digital Output Terminal 3 (DO3) Communication Addr.: 0214H
Default: 109 Related Section:
Applicable Control Mode: ALL Table 7.B
Unit: N/A
Range: 0 ~ 112
Settings: See P2-18 for explanation.