Delta Electronics ASDA-AB Network Card User Manual


 
Chapter 7 Servo Parameters|ASDA-AB Series
Revision January 2009 7-11
Gain and Switch
Control
Mode
Parameter Name Function Default Unit
Pt Pr S T
Related
Section of
User
Manual
P2-00 KPP Proportional Position Loop Gain 35 rad/s
{ {
6.2.8
P2-01 PPR Position Loop Gain Switching Rate 100 %
{ {
---
P2-02 PFG Position Feed Forward Gain 5000
0.0001
{ {
6.2.8
P2-03 PFF
Smooth Constant of Position Feed
Forward Gain
5 ms
{ {
---
P2-04 KVP Proportional Speed Loop Gain 500 rad/s
{ { { {
6.3.6
P2-05 SPR Speed Loop Gain Switching Rate 100 %
{ { { {
---
P2-06 KVI Speed Integral Compensation 100 N/A
{ { { {
6.3.6
P2-07 SFG Speed Feed Forward Gain 0
0.0001
{ { {
6.3.6
P2-26 DST External Anti-Interference Gain 0 0.001
{ { { {
---
P2-27 GCC Gain Switching Control Selection 0 N/A
{ { { {
---
P2-28 GUT Gain Switching Time Constant 10
10ms
{ { { {
---
P2-29 GPE Gain Switching Condition 10000
pulse
Kpps
r/min
{ { { {
---
P2-31
AUT1
Auto Mode Responsiveness Level
44 N/A
{ { { {
6.3.6
P2-32
AUT2
Tuning Mode Selection
0 N/A
{ { { {
6.3.6
Explanation of symbols (marked after parameter)
() Read-only register.
() Parameter cannot be set when Servo On (when the servo drive is enabled).
() Parameter is effective only after the servo drive is restarted (after switching power off and on).
() Parameter setting values are not retained when power is off.