Delta Electronics ASDA-AB Network Card User Manual


 
Chapter 4 Display and Operation|ASDA-AB Series
Revision January 2009 4-7
4.4.2 JOG Operation
After entering parameter mode P4-05, the users can follow the following steps to perform JOG operation.
(Please also refer to Figure 4.4).
Step1. Press the SET key to display the JOG speed. (The default value is 20 r/min).
Step2. Press the UP or DOWN arrow keys to increase or decrease the desired JOG speed. (This also
can be undertaken by using the SHIFT key to move the cursor to the desired unit column (the
effected number will blink) then changed using the UP and DOWN arrow keys. The example
display in Figure 4.4 is adjusted as 100 r/min.)
Step3. Press the SET key when the desired JOG speed is set. The Servo Drive will display "JOG".
Step4. Press the UP or DOWN arrow keys to jog the motor either CCW or CW. The motor will only
rotate while the arrow key is activated.
Step5. To change JOG speed again, press the MODE key. The servo Drive will display "P4 - 05".
Press the SET key and the JOG speed will displayed again. Refer back to #2 and #3 to change
speed.
NOTE
1) JOG operation is effective only when Servo On (when the servo drive is enabled).
Figure 4.4