Delta Electronics ASDA-AB Network Card User Manual


 
Chapter 11 Specifications|ASDA-AB Series
11-12 Revision January 2009
Chart of load and operating time (ECMA-G31303)
0.1
1
10
100
1000
10000
0 50 100 150 200 250 300
Load (% rated torque)
Operating Time (seconds)
Load
Operating
Time
120% 613.1s
140% 121.4s
160% 62.6s
180% 39.4s
200% 26.4s
220% 19.8s
240% 14.5s
260% 11.4s
280% 9.1s
300% 7.1s
Chart of load and operating time (ECMA-E31305)
0.1
1
10
100
1000
0 50 100 150 200 250 300
Load (% rated torque)
Operating Time (seconds)
Load
Operating
Time
120% 185.8s
140% 36.8s
160% 19.0s
180% 12.0s
200% 8.0s
220% 6.0s
240% 4.4s
260% 3.4s
280% 2.8s
300% 2.2s