Delta Electronics ASDA-AB Network Card User Manual


 
Chapter 7 Servo Parameters|ASDA-AB Series
7-28
Revision January 2009
P1 - 01
CTL Control Mode and Output Direction Communication Addr.: 0101H
Default: 00 Related Section:
Applicable Control Mode: ALL Section 6.1
Unit: pulse (P mode), r/min (S mode), N.M (T mode)
Range: 0 ~ 1110
Settings:
not used
A
B
C
A: Control mode settings
B: Torque output direction settings
C=1: When switching to different mode, DIO (P2-10 ~ P2-22) can be reset to be the default
value of the mode you switch to.
C=0: When switching to different mode, the setting value of DIO (P2-10 ~ P2-22) will remain
the same and will not be changed.
Control Mode Settings:
Pt Pr S T Sz Tz
00
01
02
03
04
05
06
07
08
09
10
Torque Output Direction Settings:
0 1
Forward
Reverse
Pt: Position control mode (command from external signal)
Pr: Position control mode (command from internal signal)
S: Speed control mode (external signal / internal signal)
T: Torque control mode (external signal / internal signal)
Sz: Zero speed / internal speed command
Tz: Zero torque / internal torque command