Delta Electronics ASDA-AB Network Card User Manual


 
Chapter 7 Servo Parameters|ASDA-AB Series
Revision January 2009 7-39
P1 - 34
TACC Acceleration Time Communication Addr.: 0122H
Default: 200 Related Section:
Applicable Control Mode: Pr, S P1-35, P1-36, Section 6.3.3
Unit: ms
Range: 1 ~ 20000
Settings:
1st to 3rd step acceleration time.
It is used to determine the acceleration time to accelerate from 0 to its rated motor speed. (When
P1-36 is set to 0: Accel/Decel function is disabled, i.e. P1-34, P1-35 is disabled.)
P1 - 35
TDEC Deceleration Time Communication Addr.: 0123H
Default: 200 Related Section:
Applicable Control Mode: Pr, S P1-34, P1-36, Section 6.3.3
Unit: ms
Range: 1 ~ 20000
Settings:
1st to 3rd step deceleration time.
It is used to determine the deceleration time to decelerate from its rated motor speed to 0.
(When P1-36 is set to 0: Accel/Decel function is disabled, i.e. P1-34, P1-35 is disabled.)