CHAPTER 6 PCI Express card Hot Maintenance in Windows
6.4 FC Card Hot Plugging
139
C122-E175-01EN
- In case of using SVagent, “Source:SVagent, ID: 25004 Error massage” is logged in SEL when replacing,
it is no problem.
6.4.1 Hot plugging an FC card incorporated with the ETERNUS
multipath driver
This section describes the hot plugging procedure for an FC card incorporated with the ETERNUS multipath
driver.
1. Confirm physical location, segment number and bus number of target NIC.
Confirm the physical location, segment number and bus number with step 1 at 6.2.1 Replacement
procedurein 6.2 Common Hot Plugging Procedure for PCI Express cards’.
Note
In case of multi-function card, there are some cards that have same segment number, same bus number,
and different function numbers.
In this case, please perform Step.2 to Step.6 of follows respectively.
2. Confirm target device by using administration manager of the FC card, and confirm WWN, port number,
and firmware version.
Case: Emulex FC card
a Open OneCommand Manager, confirm target device with step 2.
Select Port WWN as the same type of target FC card in left pane, and select [Port Information] tab in
right pane.
See “PCI Bus Number” in [Port Attributes], and look for the device which has same bus number you
confirmed in step 1.
b See WWN and port number of target device.
Select Port WWN of target FC card in left pane, and select [port Information] tab in right pane. WWN
is written at “Port WWN” in [Port Attributes].