Fujitsu 2000 SERIES Server User Manual


 
CHAPTER 8 Chapter System Startup/Shutdown and Power Control
8.2 Partition Power on and Power off
159
C122-E175-01EN
TABLE 8.2 Power on method and Power on unit
Notes
In the following cases, confirm the details according to ‘10.2 Troubleshooting’. If the error recurs, contact your
sales representative or field engineer.
Before contacting, confirm the model name and serial number shown on the label affixed on the main unit.
Until the problem is solved, do not execute [Reset], [Force Power Off] for the partition.
- When [Power Off], [Reset], or [Force Power Off] is executed for partition, or when shutting down from
the operating system, the MMB Web-UI (Information area) status changes to “Error”.
- When the MMB Web-UI displays the status of each component, "Read Error” will be displayed in the Part
number and Serial number.
8.2.5 Procedure for Partition Power On and Power Off
There are single as well as multiple partitions. Power on /Power off operation is also the same in case of
multiple partitions. If multiple partitions share one external device, first turn off the power source for multiple
partitions; and then power off the external device. The privileges for powering on and powering off the
partitions are as follows.
TABLE 8.3 Privilege for power on and power off
User Privilege
Power on and power off privilege
Administrator
Has permission for all partitions.
Operator
Has permission for all partitions.
TABLE 8.4 Privilege for power on and power off (continued)
User Privilege
Power on and power off privilege
Partition Operator
Has permission for only the partition authorized for the user.
User
Does not have permission for any partition
CE
Does not have permission for any partition
For the details on the user privileges of the MMB Web-UI menu, see 1.1 Menu list of Web-UIin
“PRIMEQUEST 2000 series Tool Reference” (C122-E177).
8.2.6 Partition Power on by MMB
This section describes the procedure of powering on the partition by MMB.
1. Log into the MMB Web-UI.
-> [MMB Web-UI] window appears.
2. Click [Partition] - [Power Control].
-> [Power Control] window appears. This window displays only the partitions having an SB or IOU.
Power off method
Power on unit: All
partitions
Power on unit: Single partition
Remarks
MMB Web-UI, MMB
CLI
Power off is
possible
Power off is possible
Schedule operation
Power off is not
possible
Power off is not possible
Automatic operation