CHAPTER 6 PCI Express card Hot Maintenance in Windows
6.5 Hot Replacement Procedure for iSCSI
145
C122-E175-01EN
10. Confirm replaced FC card by using Device Manager.
Open Device Manager, and confirm that the target device is recognized correctly.
Note
As the follow, right-click target device in Device Manager, if there are [Enable] in displayed menu, check
[Enable].
(In case of [Disable], this work is not necessary)
6.4.2 FC card addition procedure
Referring to 6.2 Common Hot Plugging Procedure for PCI Express cards, add an FC card.
6.5 Hot Replacement Procedure for iSCSI
The prerequisites for iSCSI (NIC) hot replacement are as follows.
- The maintenance person has the Administrator privileges required for operations.
- The ETERNUS multipath driver (MPD) has been applied.
- To replace more than one card, one card at a time will be replaced.