CHAPTER 6 PCI Express card Hot Maintenance in Windows
6.5 Hot Replacement Procedure for iSCSI
150
C122-E175-01EN
6.5.2 Disconnecting MPD
This section describes the procedure for disconnecting MPD.
1. Start ETERNUS Multipath Manager.
2. Confirm the address value recorded in step 10 in 6.5.1 Confirming the incorporation of a card with MPD.
Then, place the target device offline. For a multifunction card, it is necessary to place more than one
device offline.
Note
In case of multi-function card, there are some cards that have same segment number, same bus number,
and different function numbers.
In this case, please perform Step.3 to Step.5 of follows respectively.
3. Confirm target NIC in Device Manager.
Confirm NIC with step 2-a at 6.2.1 Replacement procedure in 6.2 Common Hot Plugging Procedure for
PCI Express cards.
4. Disable target NIC in Device manager.
Disable NIC with step 2-b at 6.2.1 Replacement procedure in 6.2 Common Hot Plugging Procedure for
PCI Express cards.
5. Stop target NIC by using safely remove devices from computer.
Stop NIC with step 3 at 6.2.1 Replacement procedure in 6.2 Common Hot Plugging Procedure for PCI
Express cards.