CHAPTER 3 Component Configuration and Replacement (Add, Remove)
3.3 Replacing components
48
C122-E175-01EN
3.3.1 Replaceable components
Replaceable components and replacement conditions are listed in the table below.
TABLE 3.10 Replaceable components and replacement conditions
Component name
AC power off
(Device stop)
AC power on
status All
partitions off
status (hot
maintenance)
AC power on
target partition
off (hot
maintenance)
AC power on
target partition
on ( hot
maintenance)
PSU_P/PSU_S
Replaceable
Replaceable
Replaceable (*1)
Replaceable (*1)
FANM
Replaceable
Replaceable
Replaceable (*1)
Replaceable (*1)
FANU
Replaceable
Replaceable
Replaceable
Replaceable
FANM
Replaceable
Replaceable
Replaceable
Replaceable
SB
Replaceable
Replaceable
Replaceable
Replaceable (*5)
CPU
Replaceable
Replaceable
Replaceable
Not replaceable
DIMM
Replaceable
Replaceable
Replaceable
Not replaceable
Mezzanine
Replaceable
Replaceable
Replaceable
Not replaceable
DIMM
Replaceable
Replaceable
Replaceable
Not replaceable
PCI Express card
Replaceable
Replaceable
Replaceable
Not replaceable
FBU
Replaceable
Replaceable
Replaceable
Not replaceable
HDD/SSD
Replaceable
Replaceable
Replaceable
Replaceable (*2)
Battery
Replaceable
Replaceable
Replaceable
Not replaceable
IOU_1GbE/IOU _10GbE
Replaceable
Replaceable
Replaceable
Replaceable (*5)
PCI Express card
Replaceable
Replaceable
Replaceable
Not replaceable
DU
Replaceable
Replaceable
Replaceable
Not replaceable
PCI Express card
Replaceable
Replaceable
Replaceable
Not replaceable
FBU
Replaceable
Replaceable
Replaceable
Not replaceable
HDD/SSD
Replaceable
Replaceable
Replaceable
Replaceable (*2)
MMB
Replaceable
Replaceable (*3)
Replaceable (*3)
Replaceable (*3)
OPL
Replaceable
Not replaceable
Not replaceable
Not replaceable
MP, PDB
Replaceable
Not replaceable
Not replaceable
Not replaceable
PCI_Box
Replaceable
Replaceable
Replaceable
Not replaceable
IO_PSU
Replaceable
Replaceable
Replaceable (*1)
Replaceable (*1)
IO_FAN
Replaceable
Replaceable
Replaceable (*1)
Replaceable (*1)
PEXU
Replaceable
Replaceable
Replaceable
Not replaceable
PCI Express card
Replaceable
Replaceable
Replaceable
Replaceable (*4)
*1: Possible only in configuration.
*2: Possible only for redundancy configuration with RAID.
*3: Possible only for MMB duplication configuration.
*4: PCI hot plug function is required. Operation by maintenance staff is optional.
*5: DR function is required.
3.3.2 Component replacement conditions
This section describes the replacement conditions of each component.
PSU
The PSU unit can be replaced while the system continues operating. PSU replacement in a non-redundant
configuration requires the system to be stopped.
FAN
The FAN unit can be replaced while the system continues operating.
SB
If the DR function (SB hot remove and SB hot add) is used, the SB can be replaced even when the partition
using the SB is powered on. When the DR function is not used, the SB can be replaced if the partition using
the SB is powered off.
Remarks
Since the CPU/Mezzanine/DIMM/PCI Express card /FBU which is mounted on the SB can be replaced after
removing the SB from the device, the replacement can be done under the same conditions as the SB.
Note