CHAPTER 1 Network Environment Setup and Tool Installation
1.2 How to Configure the External Networks (Management LAN/ Maintenance LAN/Production LAN)
4
C122-E175-01EN
Name
NIC
Type
IP address
setting
method
Description
IP Address
(common)
address
(*3)
the MMB
CLI or MMB
Web-UI.
with REMCS, without using the management
LAN. The MMB also uses the IP address to
communicate with the maintenance terminal
connected to the CE port.
- Internal LAN IP address: MMB-PCH IP Address
This is a dedicated IP address for MMB communication with SVS running on the operating system in each
partition. (*6)
Internal IP
Address
MMB
(common)
(*4)
Physical IP
address
(*3)
Set it from
the MMB
Web-UI.
This is a dedicated IP address for REMCS
option.
- Console redirection IP address: Console Redirection IP Address
Console
Redirection
IP Address
BMC
Physical IP
address
(*5)
Set it from
the MMB
Web-UI.
This IP address is used to access the console
redirection function in each partition from the
PC on the management LAN. An IP address
on the management LAN is assigned to each
partition.
*1 These three addresses must have the same subnet address.
*2 The server administrator need not be concerned with individual IP addresses specified for communication.
*3 The IP address is intended only for communication with the active MMB.
*4 It is connected to the communication of the Internal LAN, and is not connected to any external network.
The assigned IP address must be in a different subnet from the management LAN, maintenance LAN, or
production LAN. The default setting is 172.30.0.1/24, and it does not have to be changed unless it is in
conflict with another subnet.
*5 This IP address is to access the console redirection function provided by BMC. It accesses BMC from the
user port on the management LAN of MMB via the dedicated network for BMC-to-MMB communication
inside the cabinet.
MMB changes the local IP address of BMC to the IP address on the management LAN by NAT. From the
PC on the management LAN, the console redirection function of BMC is used via MMB.
*6 If Disable is set for this address, neither REMCS notification nor e-mail notification in case of panic.
Remarks
- A separate subnet must be assigned to "Management LAN", "Maintenance LAN" (external network), and
"Internal LAN" (inside the cabinet LAN).
- Since "3. Internal LAN" is closed to the outside of the cabinet, the same subnet as that for "Internal LAN"
in another cabinet can be used.
- For the IP address to be assigned to "Console redirection", the same subnet as that assigned to "1.
Management LAN" must be used.
- MMB uses the following subnets permanently for internal communication.
The following subnets cannot be specified:
127.1.1.0/24
127.1.2.0/24
127.1.3.0/24
The PCH on an SB in each partition has a 100 Mb Ethernet port connected with the PCH-to-MMB
communication LAN inside the cabinet. The operating system assigns the IP address of the 100 Mb Ethernet
port.
TABLE 1.3 IP addresses for the PRIMEQUEST 2000 series server (set from the operating system in a partition)
LAN port
IP address setting
method
Description
100 MbE port on
SB (NIC in PCH)
(*1)
Set it from the OS in
each partition.
100 MbE port connected to the Internal LAN. This IP address
and the IP address of the Internal LAN IP Address in TABLE 1.2
IP addresses for the PRIMEQUEST 2000 series server (IP
addresses set from the MMB)
IP addresses for the
PRIMEQUEST 2000 series server (IP addresses set from the
MMB) are in the same subnet. An IP address must be assigned
to each partition.
LAN port in IOU
Set it from the OS in
each partition.
This depends on the partition configuration.
Network card
Set it from the OS in
Each port is connected to a network outside the cabinet. The