Fujitsu DX8000 Computer Drive User Manual


 
Chapter 5 Configuration Menu
> 5.3 Thin Provisioning Management
ETERNUS DX400/DX8000 series ETERNUSmgr User Guide Settings/Maintenance
290
Copyright 2010 FUJITSU LIMITED
P2X0-0760-02ENZ0
End of procedure
5.3.13 Progress of Balance Thin Provisioning Volume
This screen displays the progress of a balancing TPV that has been specified using the [Balance
Thin Provisioning Volume] function.
This function can be used to check the operating status of a balancing TPV. In addition, an unin-
tended balancing TPV can be stopped using this function.
The operating status that is displayed in the "Balancing Thin Provisioning Volume Progress List"
is shown below.
After the balancing of a TPV is complete, this function deletes the
working TPV and formats the working TPV. If the maximum
capacity of volumes that can be formatted concurrently is
exceeded when formatting starts, or the ETERNUS DX400/
DX8000 series is in abnormal status, the deletion or formatting of
working TPV fails, and a message to that effec t i s d i s p l a y e d . W a i t
until the current formatting process is complete, or correct the
error in the device, and then delete the working TPV (temporary
volume).
The TPP where the TPV that is being balanced belongs may be
changed to alarm state (exceeding "Caution" or "Warning"
threshold) temporarily when the balancing is being executed.
In order to recover normal status (the status before failure), the
configuration information of the ETERNUS DX400/DX8000 series
may be needed. After the balancing of a TPV has been
completed, use the [Export Configuration] function to get the
configuration information.
Click the [Progress of Balance Thin Provisioning Volume] li nk to
check a progress of balancing TPV.
Operating status of the
balancing TPV
Whether the balancing TPV is
displayed or not in the "Balancing Thin
Provisioning Volume Progress List"
Required actions
Normal In operation Displayed in the list. Unnecessary
Complete Not displayed in the list.
(Deleted from the list after completion.)
Unnecessary
Errors detected Displayed in the list. Delete the work volume
manually using this function.