Chapter 6 Settings Menu
> 6.3 Advanced Copy Settings
ETERNUS DX400/DX8000 series ETERNUSmgr User Guide Settings/Maintenance
467
Copyright 2010 FUJITSU LIMITED
P2X0-0760-02ENZ0
5 Click the [OK] button.
Returns to the [Menu] screen.
End of procedure
6.3.5 Set Advanced Copy Table Size
This screen is used to set control table size, which is used by the device firmware on CM cache
memory installed in the device, without stopping the device. When Equivalent Copy (EC), One
Point Copy (OPC), or Remote Equivalent Copy (REC) functions are in use, this control table
(hereafter: Advanced Copy table) is used to manage copy progress. Regardless of the installed
cache memory size, the following capacity is prepared for the Advanced Copy table size in
ETERNUS DX400/DX8000 series.
ETERNUS DX410/DX440: maximum 136MB
ETERNUS DX8100: maximum 136MB
ETERNUS DX8400/DX8700: maximum 528MB
Changes to the Advanced Copy table size and resolution setting will be effective from the next
session.
Copy related menus other than [Register Advanced Copy License] is
not available until the license has been registered.
The purchase of a license and "ETERNUS SF AdvancedCopy
Manager" are necessary in order to use EC/OPC/REC. Register
necessary information by using the [Register Advanced Copy License]
function after purchasing the Advanced Copy license.
When the "Advanced Copy Table size" is "0 [MB]", copy functions (EC/
OPC/REC) are not supported. In the initial setting (factory default),
"Advanced Copy Table Size" is set to "0(MB)".