Nortel Networks 201i Network Card User Manual


 
Installing the 201i server in a large Meridian 1 system Standard 1.0
42 CallPilot
Overview
Introduction
This section describes what you must do if you are installing the 201i server
in a Meridian 1 switch.
Meridian 1 I/O panel connections
On the Meridian 1, the 201i server requires two connections from the IPE
slots to the I/O panel on the rear of the switch, as follows:
One connection is for the multi I/O cable.
This connection corresponds to the left slot (when viewing the front of
the Meridian 1 switch).
The other connection is for the external SCSI device.
This connection corresponds to the right slot (when viewing the front of
the Meridian 1 switch).
For information about slot and rear bulkhead wiring, refer to the Meridian 1
System Installation and Maintenance Guide (NTP 553-3001-210).
Secondary backplane connector
The secondary backplane (DS30X) connector on the 201i server connects
the server to the second slot on the IPE shelf, thereby providing access to the
voice channels provided by that slot.
ATTENTION
To install the 201i server in an Option 11C, go to page
64. For Option 11C Mini, go to page 77. For Succession
CSE 1000, go to page 91.