- 98 -
ii: Wide space width
01 to 99 (in dots)
* In the case of industrial 2 of 5, the value is fixed to 00.
jj: Character-to-character space width
01 to 99 (in dots)
* In the case of MSI and ITF, character-to-character space width is set to 00.
k: Rotational angle of bar code
0: 0°
1: 90°
2: 180°
3: 270°
llll: Height of the bar code
0000 to 1000 (in 0.1 mm units)
mnnnnnnnnnn: Increment/decrement
(Omissible. If omitted, incrementing/decrementing is not
performed.)
m: Indicates whether to increment or decrement
+: Increment
-: Decrement
nnnnnnnnnn: Skip value
0000000000 to 9999999999
p: Selection of print or non-print of numerals under bars
(Omissible. If omitted, the numerals under the bars are not printed.)
0: Non-print
1: Print
qq: No. of zeros to be suppressed
(Omissible. If omitted, the zero suppression process is not performed.)
00 to 20
r: Designates the attachment of start/stop code
(Omissible. If omitted, the start/stop code is automatically attached.)
T: Attachment of start code only
P: Attachment of stop code only
N: Start/stop code unattached
sss------sss: Data string to be printed (Omissible)
Max. 126 digits. However, the number of digits varies depending on
the type of bar code.
tt
1
, tt
2
, tt
3
, ------, tt
20
: Link field No. (Omissible)
01 to 99 (1 to 99 can also be used.)
Up to 20 fields can be designated using commas.