Toshiba B-SX4T-GS20-QM-R Printer User Manual


 
- 70 -
(12) Alignment
If characters are not placed on one line when equal space and automatic line feed is
designated, the following steps should be performed.
Decrease the value of the character-to-character space. When characters are not placed
on one line if the value is set to 0, return the value to its default, and then reduce the
horizontal magnification for a character by 0.5.
If characters are still not placed on one line, repeatedly decrease the value of the
character-to-character space, and then reduce the horizontal magnification. When
characters are not placed on one line if the character magnification is set to 0.5 and the
character-to-character space is set to 0, the field is not drawn. (The same previous field
is not drawn.)
When “01”, “12”, “23”, or “30” is specified for the rotational angles of a character and
character string, the alignment setting (Center, Right, Equal space, or Automatic line
feed) is ignored.
(13) Data string to be printed
Drawing data can be programmed by designating the number of digits after the symbol
“=.” Up to 255 digits can be printed. However, when the font type is “r”, the maximum
number of digits is 127. If the number of digits exceeds the maximum value, the
excessive data will be discarded.
For the character code table, refer to chapter 12 “CHARACTER CODE TABLE”.
Right E q u a l s p a c eCenter
A
utomatic line feed
A
utomatic line feed
A
utomatic
Left
Character string length in the
X direction (in 0.1 mm units)
Designated origin
Line feed length
No. of lines