- 69 -
(10) Increment/decrement
Printing is performed while the data is incremented or decremented every time a label is
issued. Where the data row exceeds the maximum number of digits (40), the data row
will not be drawn. When the font type is r, 51, 52, 53, 54, or 55, the
incrementing/decrementing cannot be designated. (If it is designated, it is ignored, and
the printer operates as if there was no designation.)
Initial value 0000 0000 0000 0000 999999
INC/DEC +10 +10 +10 +10 +1
Zero suppression
Not
designated
5 3 0 3
1st label 0000 0000 000 0000 999999
2nd label 0010 0010 010 0010 000
3rd label 0020 0020 020 0020 001
4th label 0030 0030 030 0030 002
5th label 0040 0040 040 0040 003
Letters and numerals for increment/decrement
For the data string, up to 40 digits (including letters, numerals, and symbols) are
possible. Only the numerals are selected and calculated for incrementing/
decrementing, and then are returned to the previous position to draw the data.
Example of increment/decrement calculation
Initial value 00000 A0A0A 7A8/9 A2A0A
INC/DEC +1 +1 +3 -3
1st label 00000 A0A0A 7A8/9 A2A0A
2nd label 00001 A0A1A 7A9/2 A1A7A
3rd label 00002 A0A2A 7A9/5 A1A4A
4th label 00003 A0A3A 7A9/8 A1A1A
5th label 00004 A0A4A 8A0/1 A0A8A
(11) Zero suppression
No. of zeros to be suppressed
0 1 2 2 3 4 5
Data 0000 0000 0000 0A12 0123 0123 0123
Print 0000 0 00 A12 123 0123 0123
The leading zero(s) in a data row is replaced by a space(s) according to the designated
number of digits. However, if the number of digits to be suppressed is greater than the
data row, the data row will be drawn without zero suppression. Where the data row
exceeds the maximum number of digits (40), the data row will not be drawn. When the
font type is r, 51, 52, 53, 54 or 55, zero suppression is not designated. If it is designated,