Toshiba B-SX4T-GS20-QM-R Printer User Manual


 
- 243 -
6.4.2 FINE ADJUSTMENT VALUE SET COMMAND [ESC] Z2; 2
Function Sets various fine adjustment values on the printer.
Format [ESC] Z2; 2, abbbcdddeffghhhijjkllmnnoppqqrr [LF] [NUL]
Term a: Indicates the direction, forward or backward, in which a feed length fine
adjustment is to be made.
+: Backward
-: Forward
bbb: Feed length fine adjustment value
000 to 500 (in units of 0.1 mm, in steps of 0.5 mm)
(*1)
c: Indicates the direction, forward or backward, in which a cut position (or strip
position) fine adjustment is to be made.
+: Backward
-: Forward
ddd: Fine adjustment value for the cut position (or strip position)
000 to 500 (in units of 0.1 mm, in steps of 0.5 mm)
(*1)
e: Indicates whether the back feed is to be increased or decreased.
+: Increase
-: Decrease
ff: Back feed length fine adjustment value
00 to 95 (in units of 0.1 mm, in steps of 0.5 mm)
(*1)
g: Indicates the direction, positive or negative, in which the X-coordinate fine
adjustment is to be made.
+: Positive direction
-: Negative direction
hhh: X-coordinate fine adjustment value
000 to 995 (in units of 0.1 mm, in steps of 0.5 mm)
(*1)
i: Indicates whether to increase or decrease the density in the thermal transfer print
mode.
+: Increase (darker)
-: Decrease (lighter)
jj: Print density fine adjustment value (for the thermal transfer print mode)
00 to 10 (in units of 1 step)
k: Indicates whether to increase or decrease the density in the direct thermal print
mode.
+: Increase (darker)
-: Decrease (lighter)
ll: Print density fine adjustment value (for the direct thermal print mode)
00 to 10 (in units of 1 step)
m: Fine adjustment direction for the ribbon rewind motor voltage
-: Fixed as Negative (The voltage is lowered.)
nn: Fine adjustment value for the ribbon rewind motor voltage
00 to 15 (in units of 1 step)