- 113 -
This parameter is effective only for EPC Class1 Generation 2 tag type.
When a format is designated, this parameter is ignored.
When the RFID module type is the U1, the EPC area and user area are
effective.
Hxyyyyyyyy: User block password setting (Effective only when the Hibiki tag is used
for the B-SX704-RFID-U2-R.)
Designates a password to lock certain user blocks.
Up to five user blocks can be specified continuously.
For example: H4AABBCCDD,H5BBCCDDEE,H6CCDDEEFF
x: Designates a user area bank (4 to 8)
4: Bank4 (User block 1)
5: Bank5 (User block 2)
6: Bank6 (User block 3)
7: Bank7 (User block 4)
8: Bank8 (User block 5)
yyyyyyyy: User block password
Fixed to 8-digit hexadecimal number
00000000 to FFFFFFFF
Qzabcdef: Area lock designation (Effective only when the Hibiki tag is used for the B-
SX704-RFID-U2-R.)
Designates an area lock type.
Area lock type can be specified for up to eight areas continuously.
For example: Q1100000,Q4101010,Q5100010, which indicates:
Bank1:Read lock, Bank4:Read lock, Write lock, Password read/write lock
Bank5:Read lock, Password read/write lock
z: Area bank designation (1 to 8)
1: Bank1 (EPC/UII bank)
2: Bank2 (TID bank)
3: Bank3 (User area)
4: Bank4 (User block 1)
5: Bank5 (User block 2)
6: Bank6 (User block 3)
7: Bank7 (User block 4)
8: Bank8 (User block 5)
a: Read lock designation
0: Disabled
1: Enabled
b: Read permanent lock designation
0: Disabled
1: Enabled
c: Write lock designation (Effective to Bank4 to Bank8 only)
0: Disabled
1: Enabled
d: Write permanent lock designation (Effective to Bank4 to Bank8 only)
0: Disabled
1: Enabled
e: User block password read/write lock designation (Effective to Bank4 to
Bank8 only)