Toshiba B-SX4T-GS20-QM-R Printer User Manual


 
- 138 -
Notes
(1) The check digit attachment, increment/decrement, and zero suppress processes are
performed according to the following priority. If any of the conditions is improper, no
drawing will take place.
For example, the zero(s) is replaced by a space(s) as a result of zero suppression but
the modulus 10 designated to be attached cannot be calculated.
Increment/decrement > zero suppression > attachment of check digit
(2) Up to 32 fields for which incrementing/decrementing has been designated can be drawn. If
the total bit map font, outline font, and bar code increment/decrement fields exceeds 32,
drawing will take place without incrementing/decrementing any excessive field. The field to
be incremented or decremented is incremented or decremented until the Image Buffer Clear
Command ([ESC] C) is transmitted.
[Example]
c Format Command (Increment bar code No. 01 (+1))
d Format Command (Increment bar code No. 02 (+2))
e Image Buffer Clear Command
f Data Command (Bar code No. 01 “0001”)
g Data Command (Bar code No. 02 “0100”)
h Issue Command (2 labels)
i Issue Command (1 label)
j Image Buffer Clear Command
k Data Command (Bar code No. 02 “3000”)
l Issue Command (1 label)
(0100)
(0001)
(0102)
(0002)
(0104)
(0003)
(3000)