Qqrstuvw: Area lock designation (Effective only when the Hibiki tag is used for the B-
SX704-RFID-U2-R.
Designates an area lock type.
Area lock type can be specified for up to eight areas continuously.
For example: Q1100000,Q4101010,Q5100010, which indicates:
Bank1:Read lock, Bank4:Read lock, Write lock, Password read/write lock
Bank5:Read lock, Password read/write lock
q: Area bank designation (1 to 8)
1: Bank1 (EPCC/UII bank)
2: Bank2 (TID bank)
3: Bank3 (User area)
4: Bank4 (User block 1)
5: Bank5 (User block 2)
6: Bank6 (User block 3)
7: Bank7 (User block 4)
8: Bank8 (User block 5)
r: Read lock designation
0: Disabled
1: Enabled
s: Read permanent lock designation
0: Disabled
1: Enabled
t: Write lock designation (Effective to Bank4 to Bank8 only)
0: Disabled
1: Enabled
u: Write permanent lock designation (Effective to Bank4 to Bank8 only)
0: Disabled
1: Enabled
v: User block password read/write lock designation (Effective to Bank4 to
Bank8 only)
0: Disabled
1: Enabled
w: User block password read/write permanent lock designation (Effective to
Bank4 to Bank8 only)
0: Disabled
1: Enabled
NOTES:
1. Once a permanent lock is enabled for parameter s, u, or w, any
subsequent change is disabled.
2. When read/write permanent lock is selected, a read/write lock state is
retained. To permanently prohibit reading/writing a tag, enable both
the read/write lock and the read/write permanent lock. The setting
which disables the read/write lock and enables the read/write
permanent lock allows the tag to be read/written permanently.