- 276 -
LED Indication
No.
LCD Messages of
Upper line
(English)
POWER ON LINE ERROR
Printer Status
Restoration
by the
[RESTART]
key
Yes/No
Acceptance
of Status
Request
Reset
Command
Yes/No
25
RFID WRITE ERROR
{ z {
Writing data onto the RFID tag
continuously failed for the
maximum number of RFID write
retries.
Yes Yes
26
RFID ERROR
{ z {
The printer cannot communicate
with the RFID module.
No Yes
27
INPUT PASSWORD
{ z z
The printer is waiting for a
password to be entered.
No No
28
PASSWORD INVALID
{ z z
Password entered was not
correct consecutively for
three times.
No No
29
RFID CONFIG ERR
{ z z
B-SX704-RFID-U2-US-R
only
RFID module’s destination
code is not specified.
No No
NOTE 1: When a command error is found in the command sent, 16 bytes of the command code of the
error command are displayed on the upper line of the LCD. (However, [LF] and [NUL] are
not displayed.)
[Example 1] [ESC] PC001; 0A00, 0300, 2, 2, A, 00, B [LF] [NUL]
Command error
LCD display
PC001;0A00,0300,
B-SX4T V1.0A
[Example 2] [ESC] T20 G30 [LF] [NUL]
Command error
LCD display
T20G30
B-SX4T V1.0A
[Example 3] [ESC] XR; 0200, 0300, 0450, 1200, 1 [LF] [NUL]
Command error
LCD display
XR;0200,0300,045
B-SX4T V1.0A
NOTE 2: When the command error is displayed, “? (3FH)” is displayed for codes other than 20H to 7FH
and A0H to DFH.