Toshiba B-SX4T-GS20-QM-R Printer User Manual


 
- 103 -
~ In the case of PDF417 (Two-dimensional code)
Format c [ESC] XBaa; bbbb, cccc, d, ee, ff, gg, h, iiii (=jjj------jjj) [LF] [NUL]
d [ESC] XBaa; bbbb, cccc, d, ee, ff, gg, h, iiii (; kk
1
, kk
2
, kk
3
, ------, kk
20
) [LF] [NUL]
Term aa: Bar code number
00 to 31
bbbb: Print origin of X-coordinate of the bar code
Fixed as 4 digits (in 0.1 mm units)
cccc: Print origin of Y-coordinate of the bar code
4 or 5 digits (in 0.1 mm units)
d: Type of bar code
P: PDF417 (Two-dimensional code)
ee: Security level
00: Level 0
01: Level 1
02: Level 2
03: Level 3
04: Level 4
05: Level 5
06: Level 6
07: Level 7
08: Level 8
ff: 1-module width
01 to 10 (in dots)
gg: No. of columns (strings)
01 to 30
h: Rotational angle of bar code
0: 0°
1: 90°
2: 180°
3: 270°
iiii: Bar height
0000 to 0100 (in 0.1 mm units)
jjj-----jjj: Data string to be printed (Omissible)
Max. 2,000 digits
kk
1
, kk
2
, kk
3
, ------, kk
20
: Link field No. (Omissible)
01 to 99 (1 to 99 can also be used.)
Up to 20 fields can be designated using commas.