Toshiba B-SX4T-GS20-QM-R Printer User Manual


 
- 73 -
(3) The Bit Map Font Format Command may be connected to the Outline Font Format
Command when transmitted.
[ESC] P C001; 0100, 0150, 1, 1, A, 00, B [LF]
C002; 0350, 0180, 1, 1, A, 00, B [LF]
C005; 0200, 0300, 25, 2, C, +05, 00, B, +0000000001 [LF]
V01; 0500, 0400, 0100, 0100, A, 00, B [LF] [NUL]
(4) When the drawing data is changed per label issue during printing, the drawing
data field for the previous label is automatically cleared using the character string
number. Then the next drawing data is printed. Therefore, the character string
number which differs according to the drawing fields should be designated. Since
the automatic field clear is not performed between the Clear Command ([ESC] C)
and Issue Command ([ESC] XS), the fixed data may be drawn using the same
character string number. In this case, the Format Command and Data Command
should be sent alternately. (After the Issue Command is sent, the fields with the
same character string number are automatically cleared until the Clear Command
is sent.)
(5) The link field designation can be cleared by omitting the link field designation
using the same character string No. and reformatting data.
The link field designation can also be cleared by the Image Buffer Clear
Command.
(6) A print data string and the link field No. cannot be programmed at the same time.
Refer to Bit Map Font Data Command ([ESC] RC)
Outline Font Format Command ([ESC] PV)
Bar Code Format Command ([ESC] XB)