Toshiba B-SX4T-GS20-QM-R Printer User Manual


 
- 242 -
C: Plug-and-play operation mode setting
0: OFF (Plug-and-play operation is disabled.)
1: ON (Plug-and-play operation is enabled.)
D: Label end/ribbon end process setting
0: TYPE1 (When the label end state is detected, the printer stops even if it is
printing a label.)
1: TYPE2 (When the label end state is detected, the printer stops after it
completes printing a label.)
E: Pre-peel-off process setting
0: OFF (The pre-peel-off process is not performed.)
1: ON (The pre-peel-off process is performed.)
F: Back feed speed setting
0: 3 ips
1: 2 ips
G: Installed solenoid type setting
0: TYPE 1 (TDS-12C)
1: TYPE 2 (TDS-16A: Stronger pull force type)
H: MaxiCode specification setting
0: TYPE1 (Compatible with the current version)
1: TYPE2 (Special specification)
I: Forward feed standby action
0: Mode 1
1: Mode 2
J: Print head type setting
0: V1 type (B-SX4T: TPH104R2, B-SX5T: TPH128R4)
1: V2 type (B-SX4T: TPH104R7, B-SX5T: TPH128R5)
K: XML specification setting (Supported by V4.4A or Xx.x only)
0: STD
1: ORACLE
Explanation (1) This command is not executed until the printer enters an idle state.
(2) With some exceptions, the parameters set by this command take effect when the
power is turned on or the printer is reset.
*1: The value can be set in units of 0.1 mm. However, the value which is actually set
on the printer is in units of 0.5 mm. When a value from 0.0 mm to 0.4 mm is set, it
is actually set on the printer as 0.0 mm. Also when a value from 0.5 mm to 0.9
mm is set, it is actually set on the printer as 0.5 mm. This fine adjustment value is
set only when parameter “i” (Forward feed standby after an issue) is set to “1”
(Performed). If it is set to “0” (Not performed), this value is discarded.
*2 This fine adjustment value is set only when parameter “n” (Type of the control
code) is set to “3” (Any set code mode). If it is set to any value other than “3”, this
value is discarded.
*3 To specify the hex code to be set in 2 bytes of ASCII code as shown below:
Example 1: To set 36H: ”36” (33H, 36H)
Example 2: To set 42H: ”42” (34H, 32H)
Example 3: To set FFH: ”FF” (46H, 46H)