g nInit (Printer Host)
z Reset request signal from the host.
z Normally at “High” level. A low on this input causes the printer to be initialized in the
same manner as when the power is turned on.
* When “Reset process when the nInit signal is ON” is set to “OFF” in the parameter setting
in the system mode, the printer is not initialized even if it receives a low signal.
z When the nInit signal is input during printing, the printer completes printing one tag/label
which is being printed, cancels the next processing, then is initialized in the same manner
as when the power is turned on.
* When “Reset process when the nInit signal is ON” is set to “OFF” in the parameter setting
in the system mode, the next process proceeds without being canceled.
z Minimum pulse width of 0.5 µsec.
h Select (Printer Host)
z This is an output signal which indicates whether the printer is in Pause state or placed
online. The printer can receive data while placed online.
z The signal is at “Low” level while the printer is in a Pause state.
z The signal is kept at “Low” level (in a Pause state) until the current state (one of the
following states) is reset.
Pause state caused by the [PAUSE] key
Paper end state
Ribbon end state
Head open state
Printer error state
Initialization in progress upon power on or receipt of the nInit signal
i nFault (Printer Host)
z Output signal indicating that the printer is in a Fault state.
z At “Low” level while the printer is in a Fault state.
z The signal is kept at “Low” level (in a Fault state) until the current state (one of the
following states) is reset.
Pause state caused by the [PAUSE] key
Paper end state
Ribbon end state
Head open state
Printer error state
Initialization in progress upon power on or receipt of the nInit signal
j PError (Printer Host)
z Output signal indicating a label end or ribbon end state.
z At “High” level when the printer is in a label end or ribbon end state.
z Turns to “Low” level when the label end or ribbon end state is reset.
k +5 V
z This is not a signal but a +5 V power supply voltage.
z The maximum current of 500 mA can be taken out.
l nSelectIn (Printer Host)
z Not used
11 nAutoFd (Printer Host)
z Not used