Toshiba B-SX4T-GS20-QM-R Printer User Manual


 
- 102 -
h: Rotational angle of bar code
0: 0°
1: 90°
2: 180°
3: 270°
Ciiijjj: No. of cells
(Omissible. If omitted, it is automatically set.)
iii: No. of cells in the X direction 000 to 144
jjj: No. of cells in the Y direction 000 to 144
* Cell setting varies according to the ECC type.
ECC0 to ECC140 ECC200
No. of cells to be
designated
Odd numbers only Even numbers only
Min./Max. No. of cells 9 × 9 to 49 × 49 10 × 10 to 144 × 144
Rectangular code None 18 × 8
32 × 8
26 × 12
36 × 12
36 × 16
48 × 16
• When this parameter is omitted, the number of cells is automatically
set. Also, when any data other than the above values are
designated for the number of cells in the X and Y directions, the
number of cells are automatically set.
Jkkllmmmnnn: Connection setting
(Omissible. No connection if this parameter is omitted.)
kk: Code number 01 to 16
ll: No. of divided codes 02 to 16
mmm: ID number 1 001 to 254
nnn: ID number 2 001 to 254
ooo ------ ooo: Data string to be printed (Omissible)
Max. 2000 digits.
pp
1
, pp
2
, pp
3
, ------, pp
20
: Link field No. (Omissible)
01 to 99 (1 to 99 can also be used.)
Up to 20 fields can be designated using commas.