- 240 -
g: RS-232C transmission control
0: XON/XOFF protocol
(No XON output when the power is turned on, no XOFF output when the
power is turned OFF)
1: READY/BUSY (DTR) protocol
(No XON output when the power is turned on, no XOFF output when the
power is turned OFF)
2: XON/XOFF + READY/BUSY (DTR) protocol:
(XON output when the power is turned on, XOFF output when the power is
turned OFF)
3: XON/XOFF protocol:
(XON output when the power is turned on, XOFF output when the power is
turned OFF)
4: RTS protocol
(No XON output when the power is turned on, no XOFF output when the
power is turned OFF)
h: Language for LCD messages
0: ENGLISH
1: GERMAN
2: FRENCH
3: DUTCH
4: SPANISH
5: JAPANESE
6: ITALIAN
i: Forward feed standby after an issue
0: OFF (Not performed)
1: ON (Performed)
j: Fine adjustment direction for the stop position of the forward feed standby
+: Increase the length of the forward feed
-: Decrease the length of the forward feed
kk: Fine adjustment value for the stop position of the forward feed standby
00 to 50 (in units of 0.1 mm, in steps of 0.5 mm)
(*1)
l: Head-up operation in the cut issue mode, or the use of the rewinder in the batch
issue mode.
0: OFF (Head-up operation is not performed/the rewinder is not used.)
1: ON (Head-up operation is performed/the rewinder is used.)
m: Ribbon saving system
0: OFF (Not used)
1: ON (Head lever position is “TAG”)
2: ON (Head lever position is “LABEL”)
n: Type of control code
0: Automatic selection
1: ESC, LF, NUL mode
2: {, |, } mode
3: Any set code mode