Toshiba B-SX4T-GS20-QM-R Printer User Manual


 
- 148 -
6.3.12 OUTLINE FONT DATA COMMAND [ESC] RV
Function Provides data for the outline font row.
Format c [ESC] RVaa; bbb ------ bbb [LF] [NUL]
d Link Field Data Command
[ESC] RV; ccc ------ ccc [LF] ddd ------ ddd [LF] ------ [LF] xxx ------ xxx [LF] [NUL]
Term aa: Character string number
00 to 99
bbb ------ bbb: Data string to be printed
Max. 255 digits
Any excess data will be discarded.
For the character codes, refer to chapter 12 “CHARACTER CODE
TABLE”.
ccc ------ ccc: Data string of link field No. 1
ddd ------ ddd: Data string of link field No. 2
to
xxx ------ xxx: Data string of link field No. 99
Note: If the Outline Font Data Command is sent without entering any data string for the
specified character string number (e.g. [ESC]RV00;[LF][NUL]), the previous data
string of the same character string number (No. 00 in the case of the above
example) is deleted.
Explanation (1) Link field data string
After the link field No. is designated in the Format Command, data strings are
linked using the Link Field Data Command to draw an image.
• Up to 255 digits of data strings can be linked. Data exceeding the max.
number of digits will be discarded.
Up to 99 data strings can be linked.
• Up to 2048 bytes can be used as the command length ([ESC] to [NUL]) of the
Link Field Data Command.
When the data string is omitted in the Link Field Data Command, the following
process is performed:
c No process will be performed for the field which contains no print data due to
the omission.
d When the field partially loses print data due to the omission, the only
remaining data will be processed as print data.
The Link Field Data Command can be used for the bit map font fields, outline
font fields, and bar code fields.
(The same result is obtained when any of the “RC,” “RV” or “RB” command
code is designated.)
Refer to Outline Font Format Command ([ESC] PV)