~ In the case of GS1 DataBar
Format c [ESC] XBaa; bbbb, cccc, d, e, ff, g, hhhh (, ijjjjjjjjjj, kk) (, Sll) (= sss ------ sss) [LF]
[NUL]
d [ESC] XBaa; bbbb, cccc, d, e, ff, g, hhhh (, ijjjjjjjjjj, kk) (, Sll) (; tt
1
, tt
2
, tt
3
, ------, tt
20
)
[LF] [NUL]
Term aa: Bar code number
00 to 31
bbbb: Print origin of X-coordinate of the bar code
Fixed as 4 digits (in 0.1 mm units)
cccc: Print origin of Y-coordinate of the bar code
4 or 5 digits (in 0.1 mm units)
d: Type of bar code
b: GS1 DataBar family
e: Version (Type of GS1 DataBar)
1: GS1 DataBar Omnidirectional/GS1 DataBar Truncated
2: GS1 DataBar Stacked
3: GS1 DataBar Stacked Omnidirectional
4: GS1 DataBar Limited
5: GS1 DataBar Expanded
6: GS1 DataBar Expanded Stacked
ff: 1-module width
01 to 15 (in dots)
g: Rotational angle of bar code
0: 0°
1: 90°
2: 180°
3: 270°
hhhh: Height of the bar code
0000 to 1000 (in 0.1 mm units)
In the case of GS1 DataBar Truncated, set a value obtained by multiplying
one module width by 13.
ijjjjjjjjjj: Increment/decrement
(Omissible. If omitted, incrementing/decrementing is not performed.)
i: Indicates whether to increment or decrement
+: Increment
-: Decrement
jjjjjjjjjj: Skip value
0000000000 to 9999999999
kk: No. of zeros to be suppressed
(Omissible. If omitted, the zero suppression process is not performed.)
00 to 20
ll: Segment width (Omissible. When omitted, “04” is specified.)
02 to 22 (Even number only. Specifying an odd number causes a
command error.)
This parameter is effective only for GS1 DataBar Expanded Stacked.
(Version (type of GS1 DataBar): 6)
Setting this parameter to ”22” makes the symbol look similar to the GS1