Emerson BACNET IP Power Supply User Manual


 
Modbus 485 and Modbus IP Protocols - Thermal Management Products
Liebert
®
IntelliSlot
®
Modbus/BACnet IP 10
RAM Battery Issue 10227 1 Active on Alarm 1, 2, 3, 4, 5, 6
Water Leakage Detector Sensor Issue 10228 1 Active on Alarm 1, 2, 3, 4, 5, 6
External Fire Detected 10229 1 Active on Alarm 1, 2, 3, 4, 5, 6
Chilled Water Control Valve Failure 1 10230 1 Active on Alarm 1, 2, 3, 4, 5, 6
Chilled Water Control Valve Failure 2 10231 1 Active on Alarm 1, 2, 3, 4, 5, 6
Unit Off 10232 1 Active on Alarm 1, 2, 3, 4, 5, 6
Unit On 10233 1 Active on Alarm 1, 2, 3, 4, 5, 6
Unit Partial Shutdown 10234 1 Active on Alarm 1, 2, 3, 4, 5, 6
Unit Shutdown 10235 1 Active on Alarm 1, 2, 3, 4, 5, 6
High Power Shutdown 10236 1 Active on Alarm 1, 2, 3, 4, 5, 6
Unit Standby 10237 1 Active on Alarm 1, 2, 3, 4, 5, 6
Maintenance Due 10238 1 Active on Alarm 1, 2, 3, 4, 5, 6
Maintenance Completed 10239 1 Active on Alarm 1, 2, 3, 4, 5, 6
Compressor Low Pressure Transducer Issue 1 10240 1 Active on Alarm 1, 2, 3, 4, 5, 6
Compressor Low Pressure Transducer Issue 2 10241 1 Active on Alarm 1, 2, 3, 4, 5, 6
Compressor High Pressure Transducer Issue 1 10242 1 Active on Alarm 1, 2, 3, 4, 5, 6
Compressor High Pressure Transducer Issue 2 10243 1 Active on Alarm 1, 2, 3, 4, 5, 6
Compressor Capacity Reduced 10244 1 Active on Alarm 1, 2, 3, 4, 5, 6
Dew Point Over Temperature 10345 1 Active on Alarm 2, 3, 4, 5, 6
Dew Point Under Temperature 10346 1 Active on Alarm 2, 3, 4, 5, 6
Ext Dew Point Over Temperature 10347 1 Active on Alarm 2, 3, 4, 5, 6
Ext Dew Point Under Temperature 10348 1 Active on Alarm 2, 3, 4, 5, 6
Compressor Superheat Over Threshold 1 10349 1 Active on Alarm 2, 3, 4, 5, 6
Compressor Superheat Over Threshold 2 10350 1 Active on Alarm 2, 3, 4, 5, 6
Unspecified General Event 10351 1 Active on Alarm 2, 3, 4, 5, 6
Remote Sensor Average Over Temperature 10352 1 Active on Alarm 2, 3, 4, 5, 6
Remote Sensor Average Under Temperature 10353 1 Active on Alarm 2, 3, 4, 5, 6
Remote Sensor System Average Over Temperature 10354 1 Active on Alarm 2, 3, 4, 5, 6
Remote Sensor System Average Under Temperature 10355 1 Active on Alarm 2, 3, 4, 5, 6
Remote Sensor Over Temperature 1 10356 1 Active on Alarm 2, 3, 4, 5, 6
Remote Sensor Over Temperature 2 10357 1 Active on Alarm 2, 3, 4, 5, 6
Remote Sensor Over Temperature 3 10358 1 Active on Alarm 2, 3, 4, 5, 6
Remote Sensor Over Temperature 4 10359 1 Active on Alarm 2, 3, 4, 5, 6
Remote Sensor Over Temperature 5 10360 1 Active on Alarm 2, 3, 4, 5, 6
Table 6 Liebert Challenger 3000
, Liebert Challenger ITR
, Liebert CW
, Liebert Deluxe System/3
,
Liebert DS
, Liebert DSE
, Liebert HPM
, Liebert PeX
- Status and Coil (continued)
Controller Liebert iCOM
®
v4
Liebert Products
Units with
Liebert iCOM
®
:
Liebert HPM
Units with Liebert iCOM Firmware
PA1.04.033.STD or later:
Liebert Challenger 3000
Liebert Challenger ITR
Liebert CW
Liebert Deluxe System/3
Liebert DS
Liebert DSE
Liebert PeX
Available Points
Data Label
Status Coil
Number
of Bits Notes / Units Extra Notes