Emerson BACNET IP Power Supply User Manual


 
BACnet Communications - UPS Systems
301 Liebert
®
IntelliSlot
®
Modbus/BACnet IP
Table 99 Liebert APM
, Liebert NXC
, Liebert NXR
- Analog Data
Data Label
Object
Type Instance
Object
Name Access Notes
System Input RMS A-B Analog_Value 1 4097_1 RD Units: VAC
System Input RMS B-C Analog_Value 2 4099_1 RD Units: VAC
System Input RMS C-A Analog_Value 3 4101_1 RD Units: VAC
System Input RMS Current Phase A Analog_Value 4 4113_1 RD Units: A AC
System Input RMS Current Phase B Analog_Value 5 4114_1 RD Units: A AC
System Input RMS Current Phase C Analog_Value 6 4115_1 RD Units: A AC
System Input Frequency Analog_Value 7 4105_1 RD Units: Hz
System Input RMS A-N Analog_Value 8 4096_1 RD Units: VAC
System Input RMS B-N Analog_Value 9 4098_1 RD Units: VAC
System Input RMS C-N Analog_Value 10 4100_1 RD Units: VAC
System Input Power Factor Phs A Analog_Value 11 4116_1 RD
System Input Power Factor Phs B Analog_Value 12 4117_1 RD
System Input Power Factor Phs C Analog_Value 13 4118_1 RD
Bypass
Bypass Input Voltage RMS A-N Analog_Value 24 4128_1 RD Units: VAC
Bypass Input Voltage RMS B-N Analog_Value 25 4129_1 RD Units: VAC
Bypass Input Voltage RMS C-N Analog_Value 26 4130_1 RD Units: VAC
Bypass Input Frequency Analog_Value 27 4131_1 RD Units: Hz
Battery
Battery Time Remaining Analog_Value 38 4150_1 RD Units: min
Battery Volts for Cabinet Analog_Value 39 4155_1 RD Units: VDC
Battery Temperature for Cabinet Analog_Value 40 4156_1 RD Units: deg C
Battery Temperature for Cabinet Analog_Value 10040 4156_1_deg_F RD Units: deg F
Inlet Air Temperature Analog_Value 41 4291_1 RD Units: deg C
Inlet Air Temperature Analog_Value 10041 4291_1_deg_F RD Units: deg F
DC Bus Current Analog_Value 42 4149_1 RD Units: A DC
Output
System Output Voltage RMS A-N Analog_Value 53 4385_1 RD Units: VAC
System Output Voltage RMS B-N Analog_Value 54 4386_1 RD Units: VAC
System Output Voltage RMS C-N Analog_Value 55 4387_1 RD Units: VAC
System Output RMS Current Phs A Analog_Value 56 4204_1 RD Units: A AC
System Output RMS Current Phs B Analog_Value 57 4205_1 RD Units: A AC
System Output RMS Current Phs C Analog_Value 58 4206_1 RD Units: A AC
System Output Frequency Analog_Value 59 4207_1 RD Units: Hz
System Output Voltage RMS A-B Analog_Value 60 4201_1 RD Units: VAC
System Output Voltage RMS B-C Analog_Value 61 4202_1 RD Units: VAC
System Output Voltage RMS C-A Analog_Value 62 4203_1 RD Units: VAC
System Output Power Factor Phs A Analog_Value 63 4210_1 RD
System Output Power Factor Phs B Analog_Value 64 4211_1 RD
System Output Power Factor Phs C Analog_Value 65 4212_1 RD
System Output Pct Power Phase A Analog_Value 66 4223_1 RD Units: %
System Output Pct Power Phase B Analog_Value 67 4224_1 RD Units: %
System Output Pct Power Phase C Analog_Value 68 4225_1 RD Units: %