Synology DS411SLIM Server User Manual


 
Synology DiskStation User's Guide
Based on DSM 3.1
195 Chapter 14: Safeguard Your Environment with Surveillance Station
3 Name your client, enter its IP address, port number, and authentication key (5000 by default), and then click
Test Client.
4 If the values are correct, a dialog will appear to tell you the connection is successful. Click OK to close the
dialog.
Now you can see the live view and recorded events of the client through Live View or Event Playback page
VisualStation
1
Tick Enable VisualStation to manage the VisualStation with your DiskStation. With VisualStation, you can see
the live view of the cameras on a TV set or LCD monitor directly without using a computer. A VisualStation can
only be managed by a DiskStation within the same LAN.
MPEG4 Streaming Port Range
2
1 The default port range for MPEG4 video streaming is 55736-55863. You can set it from 1025 to 65535,
excluding the following numbers:
3306, 3689, 5335, 5432, 7000, 7001, 8080, 8081, 9997, 9998, 9999, 50001, 50002, 55536-55663, 6881-6890.
2 The port range must include sufficient number of ports for MPEG4 video streaming, and can include up to 128
ports.
Video Output Module
When DirectX is set as the video output module, live view or events might not display correctly with some
computers due to video card performance. This problem may be fixed by using OpenGL instead.
Note:
1 Only editable by the admin.
2 After the port range is modified, all live views will be interrupted and reactivated.