6
6 - 2e-STUDIO350/352/353/450/452/453
SCANNER
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
6.2 Construction
a. Exposure lamp
This lamp is the light source to irradiate the original on the glass. (One 16W xenon lamp)
b. Lamp inverter
Controls lighting of the xenon lamp.
c. Reector
Thisisaplatetoefcientlydirectthelightfromtheexposurelamptothesurfaceoftheoriginal
on the glass.
d. Mirror-1
Thismirrordirectsthelightreectedfromtheoriginaltothemirror-2describedlater.
Fig. 6-202
Fig. 6-201
The following shows the construction and purpose of the scanning system:
(1) Original glass
This is a glass on which original is placed. The light from the exposure lamp is irradiated to the
original through this glass.
(2) Carriage-1
Carriage-1consistsoftheexposurelamp,lampinverters,reector,mirror-1,etc.Itisdrivenby
the scan motor and scans an original on the glass.
Reector
Lamp inverter
Exposure lamp
Mirror-1
Original glass
Original
Exposure lamp
Lamp inverter
Reector
Mirror-1