Toshiba 350 All in One Printer User Manual


 
e-STUDIO350/352/353/450/452/453
DEVELOPMENT SYSTEM
12
12 - 13
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
Notes:
1. When installing the developer sleeve unit,
make sure that the side seals (urethane seal) of
the front and rear sides do not come out of the
case.
2. When installing the doctor blade, make the gap
adjustment of the doctor sleeve.
Fig. 12-520
Fig. 12-521
Fig. 12-522
Fig. 12-523
[G] Mixer-1
(1) Discharge the developer material
( Chapter 12.5 (B-1)).
(2) Take off the developer sleeve unit
(
Chapter 12.5 [F]).
(3) Take off the bushing on the front side.
*Replacement of Oil Seal ( Page 12-15)
(4) Remove 1 E-ring and 1 bushing. Then take
off the mixer-1.
[H] Mixer-2
(1) Discharge the developer material
( Chapter 12.5 (B-1)).
(2) Take off the developer sleeve unit
( Chapter 12.5 [F]).
(3) Remove 1 E-ring and 1 bushing on the front
side.
(4) Remove 1 screw and holder.
*Replacement of Oil Seal ( Page 12-15)
Holder
Oil seal
Bushing
Bushing
Oil seal
Bushing