Emerson MODBUS IP Power Supply User Manual


 
Modbus 485 and Modbus IP Protocols - Thermal Management Products
31 Liebert
®
IntelliSlot
®
Modbus/BACnet IP
Ext Dew Point Over Temp
Threshold
Threshold value used in the [Ext Dew Point Over Temperature] event.
Ext Dew Point Over Temperature
At least one dew point temperature reading ([Ext Air Sensor A Dew Point Temp], [Ext
Air Sensor B Dew Point Temp]...) has exceeded [Ext Dew Point Over Temp
Threshold].
Ext Dew Point Under Temp
Threshold
Threshold value used in the [Ext Dew Point Under Temperature] event.
Ext Dew Point Under Temperature
At least one dew point temperature reading ([Ext Air Sensor A Dew Point Temp], [Ext
Air Sensor B Dew Point Temp]...) has dropped below [Ext Dew Point Under Temp
Threshold].
Ext Free Cooling Lockout - Event
Control
Enable/disable the activation of the [Ext Free Cooling Lockout] event. If set to
'disabled', the event will not be annunciated. This implies that the event will not be
placed in any active event list or in any event history list.
Ext Free Cooling Lockout - Event
Type
The event type for the [Ext Free Cooling Lockout] event.
Ext Free Cooling Lockout Free cooling is disabled by an external input signal.
Ext Humidifier Lockout - Event
Control
Enable/disable the activation of the [Ext Humidifier Lockout] event. If set to 'disabled',
the event will not be annunciated. This implies that the event will not be placed in any
active event list or in any event history list.
Ext Humidifier Lockout - Event
Type
The event type for the [Ext Humidifier Lockout] event.
Ext Humidifier Lockout The humidifier is shut down and disabled by an external input signal.
Ext Loss of Air Blower - Event
Control
Enable/disable the activation of the [Ext Loss of Air Blower] event. If set to 'disabled',
the event will not be annunciated. This implies that the event will not be placed in any
active event list or in any event history list.
Ext Loss of Air Blower - Event Type The event type for the [Ext Loss of Air Blower] event.
Ext Loss of Air Blower Loss of air blower is detected, as indicated by an external input signal.
Ext Loss of Flow - Event Control
Enable/disable the activation of the [Ext Loss of Flow] event. If set to 'disabled', the
event will not be annunciated. This implies that the event will not be placed in any
active event list or in any event history list.
Ext Loss of Flow - Event Type The event type for the [Ext Loss of Flow] event.
Ext Loss of Flow Loss of flow is detected, as indicated by an external input signal.
Ext Over Temperature - Event
Control
Enable/disable the activation of the [Ext Over Temperature] event. If set to 'disabled',
the event will not be annunciated. This implies that the event will not be placed in any
active event list or in any event history list.
Ext Over Temperature - Event
Type
The event type for the [Ext Over Temperature] event.
Ext Over Temperature A temperature has exceeded its threshold, as indicated by an external input signal.
Ext Power Source A Failure Unit main power source A failure, as indicated by an external input signal.
Ext Power Source B Failure Unit main power source B failure, as indicated by an external input signal.
Ext Reheat Lockout - Event
Control
Enable/disable the activation of the [Ext Reheat Lockout] event. If set to 'disabled', the
event will not be annunciated. This implies that the event will not be placed in any
active event list or in any event history list.
Ext Reheat Lockout - Event Type The event type for the [Ext Reheat Lockout] event.
Ext Reheat Lockout The reheater is shut down and disabled by an external input signal.
Ext Standby Glycol Pump On -
Event Control
Enable/disable the activation of the [Ext Standby Glycol Pump On] event. If set to
'disabled', the event will not be annunciated. This implies that the event will not be
placed in any active event list or in any event history list.
Table 10 Liebert Challenger 3000
, Liebert Challenger ITR
, Liebert CW
, Liebert Deluxe System/3
,
Liebert DS
, Liebert DSE
, Liebert HPM
, Liebert PeX
- Glossary (continued)
Controller Liebert iCOM
®
v4
Data Label Data Description