Lantronix 900-510 Switch User Manual


 
8: Device Ports
SLB™ Branch Office Manager User Guide 106
To configure console port settings:
set consoleport <one or more parameters>
Parameters:
baud <300-115200>
databits <7|8>
stopbits <1|2>
parity <none|odd|even>
flowcontrol <none|xon/xoff|rts/cts>
showlines <enable|disable>
timeout <disable|1-30>
To view console port settings:
show consoleport
Power Outlets
The SLB branch office manager has four outlets that can provide power to other units in
an IT environment. Each outlet can be configured and controlled through the SLB device.
The SLB can issue an SNMP trap if the total current for all four outlets exceeds a
specified threshold.
To configure a power outlet:
1. Click the Devices tab and select the Power Outlets option. The following page
displays:
Note: The four red buttons (P1-P4) at the top of any page display the Device Ports
Power Outlets page.