Lantronix 900-510 Switch User Manual


 
8: Device Ports
SLB™ Branch Office Manager User Guide 94
Humidity (%)
Current relative humidity on the device the sensor is
monitoring.
Low Humidity
Enter the relative humidity permitted on the device the
sensor is monitoring below which the sensor sends a trap to
the SLB branch office manager.
High Humidity
Enter the highest relative acceptable humidity permitted on
the device above which the sensor sends a trap to the SLB
device.
Traps
Select to indicate the SLB branch office manager should
send a trap or configured Event Alert when the sensor
detects an out-of-range configured threshold.
4. Click the Apply button.
5. To view the status detected by the Sensorsoft, click the Sensorsoft Status link to
the right of the table.
Device Port Commands
The following CLI commands correspond to the web page entries described above.
To configure a single port or a group of ports:
Example: set deviceport port 2-5,6,12,15-16 baud 2400
set deviceport port <Device Port List or Name> <one or more
device port parameters>
Parameters:
auth <pap|chap>
banner <Banner Text>
baud <300-115200>
breakseq <1-10 Chars>
calleridcmd <Modem Command String>
calleridlogging <enable|disable>
chaphost <CHAP Host or User Name>
chapsecret <CHAP Secret or User Password>
The user defines the secret.
checkdsr <enable|disable>
closedsr <enable|disable>
databits <7|8>
device <none|slp8|slp16>
dialinlist <Host List for Dial-in>
dialoutnumber <Phone Number>
dialoutlogin <User Login>