Texas Instruments TI-83 Calculator User Manual


 
11-14 Lists
8311LIST.DOC TI-83 international English Bob Fedorisko Revised: 02/19/01 1:21 PM Printed: 02/19/01 1:37 PM
Page 14 of 18
6. Press
Í
. A
4
indicator on the graph screen shows
the left bound.
Right Bound? is displayed in the bottom-
left corner.
7. Press
|
or
~
to move the cursor to the stat plot point
that you want for the right bound, and then press
Í
.
The x-values and y-values of the selected points are
stored in
xlistname
and
ylistname
. A new stat plot of
xlistname
and
ylistname
replaces the stat plot from
which you selected data points. The list names are
updated in the stat plot editor.
Note:
The two new lists (
xlistname
and
ylistname
) will include the
points you select as left bound and right bound. Also,
left-bound
x-value
right-bound x-value
must be true.