Chapter 42 Command Examples
IES-612-51A User’s Guide
279
Sync with timeserver
<ip> failed!
WARN The device was not able to synchronize the time with the time server at the
listed IP address.
Sync with timeserver
<ip> successful!
INFO The device synchronized the time with the time server at the listed IP
address.
Received File <file>! INFO A file was uploaded to the IES-612-51A by FTP.
<file> - received file’s name
Received Firmware
Checksum Error!
WARN A checksum error was detected during an attempted FTP firmware upload.
Received Firmware
Invalid!
WARN Someone attempted to upload a firmware file with a wrong identity via FTP.
Received Firmware Size
too large!
WARN The file size was too large with an attempted FTP firmware upload.
THERMO LOW VOLTAGE:
dev: <id> limit:
<threshold> value:
<voltage>!
WARN The device’s voltage went above the accepted operating range.
<id> 1=1.2 V, 2=1.8 V, 3=3.3 V, 4=18 V
<threshold> - voltage limit
<voltage> - voltage of the DC power when logged
THERMO LOW
TEMPERATURE: dev:<id>
threshold:<threshold>
(degree C)
value:<temp>(degree
C)!
WARN The temperature was too low at one of the temperature sensors.
<id> -
0: sensor near the ADSL chipset
1: sensor near the CPU
2: thermal sensor chip
<threshold> - temperature limit
<temp> - temperature when the entry was logged
THERMO OVER
TEMPERATURE: dev:<id>
threshold:<threshold>
(degree C)
value:<temp>(degree
C)!
WARN The temperature was too high at one of the temperature sensors.
<id> -
0: sensor near the ADSL chipset
1: sensor near the CPU
2: thermal sensor chip
<threshold> - temperature limit
<temp> - temperature when the entry was logged
THERMO OVER
TEMPERATURE released:
dev:<id>
threshold:<threshold>
(degree C)
value:<temp>(degree
C)!
INFO The temperature at one of the temperature sensors has come back to
normal.
<id> -
0: sensor near the ADSL chipset
1: sensor near the CPU
2: thermal sensor chip
<threshold> - temperature limit
<temp> - temperature when the entry was logged
THERMO OVER VOLTAGE:
dev: <id> limit:
<threshold> value:
<voltage>!
WARN The voltage at one of the voltage sensors went above the accepted
operating range.
<id> 1=1.2v, 2=1.8v, 3=3.3v, 4=24v
<threshold> - voltage limit
<voltage> - voltage of the DC power when logged
THERMO OVER VOLTAGE
released:
nominal:<nominal>(mV)
value:<voltage> (mV)!
INFO The device’s voltage is back inside the accepted operating range.
<nominal> - nominal voltage of the DC power
<voltage> - voltage of the DC power when logged
Table 90 Log Messages (continued)
LOG MESSAGE TYPE DESCRIPTION