Chapter 43 Alarm Commands
IES-612-51A User’s Guide
284
The following example displays the current critical level alarms for all alarm categories and
conditions.
The source is where the alarm originated. This is either a DSL port number, one of the
Ethernet ports (enet 1 or 2), or “eqpt” for the system itself.
43.4 Alarm Port Show Command
Syntax:
ras> alarm port show [<severity>|all]
This command displays port alarm severity level thresholds. The system reports an alarm on a
port if the alarm has a severity equal to or higher than the port’s threshold.
Figure 138 Alarm Show Command Example
ras> alarm tablelist
no alarm condition facility snmp syslog severity
clearable
--- ----- ------------------------- -------- ---- ------ -------- -------
1 dsl ( 5000)line_up local1 V V info -
2 dsl ( 5001)line_down local1 V V minor V
3 dsl ( 5002)ad_perf_lol_thresh local1 V V minor V
4 dsl ( 5003)ad_perf_lof_thresh local1 V V minor V
5 dsl ( 5004)ad_perf_los_thresh local1 V V minor V
6 dsl ( 5005)ad_perf_lop_thresh local1 V V minor V
7 dsl ( 5006)ad_perf_es_thresh local1 V V minor V
8 dsl ( 5007)ad_perf_ses_thresh local1 V V minor V
9 dsl ( 5008)ad_perf_uas_thresh local1 V V minor V
10 dsl ( 5009)ad_atuc_loftrap local1 V V minor -
11 dsl ( 5010)ad_atuc_lostrap local1 V V minor -
12 dsl ( 5011)ad_atur_loftrap local1 V V minor -
13 dsl ( 5012)ad_atur_lostrap local1 V V minor -
14 dsl ( 5013)ad_atur_lprtrap local1 V V minor -
15 eqpt (10000)vol_err local1 V V critical -
16 eqpt (10001)temp_err local1 V V critical -
17 eqpt (10002)hw_rtc_fail local1 V V critical -
18 eqpt (10003)hw_mon_fail local1 V V critical -
19 eqpt (10004)cold_start local1 V V info -
Press any key to continue, 'e' to exit, 'n' for nopause