ZyXEL Communications IES-612-51A Modem User Manual


 
Chapter 43 Alarm Commands
IES-612-51A User’s Guide
286
This command lists alarm settings.
The following example displays the supported minor level alarms for all alarm categories,
facilities, types of alarm messages and conditions.
43.7 Log Format
The following table describes the columns in the list.
Figure 141 Alarm Tablelist Command Example
ras> alarm table
no alarm condition facility snmp syslog severity
clearable
--- ----- ------------------------- -------- ---- ------ -------- -------
1 dsl ( 5000)line_up local1 V V info -
2 dsl ( 5001)line_down local1 V V minor V
3 dsl ( 5002)ad_perf_lol_thresh local1 V V minor V
4 dsl ( 5003)ad_perf_lof_thresh local1 V V minor V
5 dsl ( 5004)ad_perf_los_thresh local1 V V minor V
6 dsl ( 5005)ad_perf_lop_thresh local1 V V minor V
7 dsl ( 5006)ad_perf_es_thresh local1 V V minor V
8 dsl ( 5007)ad_perf_ses_thresh local1 V V minor V
9 dsl ( 5008)ad_perf_uas_thresh local1 V V minor V
10 dsl ( 5009)ad_atuc_loftrap local1 V V minor -
11 dsl ( 5010)ad_atuc_lostrap local1 V V minor -
12 dsl ( 5011)ad_atur_loftrap local1 V V minor -
13 dsl ( 5012)ad_atur_lostrap local1 V V minor -
14 dsl ( 5013)ad_atur_lprtrap local1 V V minor -
15 eqpt (10000)vol_err local1 V V critical -
16 eqpt (10001)temp_err local1 V V critical -
17 eqpt (10002)hw_rtc_fail local1 V V critical -
18 eqpt (10003)hw_mon_fail local1 V V critical -
19 eqpt (10004)cold_start local1 V V info -
==================================== SNIP =================================
Table 92 Log Format
LABEL DESCRIPTION
no This is the index number of the alarm entry in this list display.
alarm This is the category of alarms. eqpt represents equipment alarms. dsl
represents Digital Subscriber Line (DSL) alarms. enet represents Ethernet
alarms. sys represents system alarms.
condition There is a condition code number for the specific alarm message and a text
description for the condition under which the alarm applies.
facility This is the log facility (local1~local7) on the syslog server where the system is to
log this alarm. This is for alarms that send alarms to a syslog server.
snmp This displays “V” if the system is to send this alarm to an SNMP server. It
displays “-“ if the system does not send this alarm to an SNMP server.
syslog This displays “V” if the system is to send this alarm to a syslog server. It displays
“-“ if the system does not send this alarm to a syslog server.
severity This is the alarm severity level (critical, major, minor or info).
clearable This displays “V” if the alarm clear command removes the alarm from the
system. It displays “-“if the alarm clear command does not remove the alarm
from the system.