104 Avaya CMS Sun Ultra 5 Computer Hardware Installation, Maintenance, and Troubleshooting
The following figure shows the SCSI cabling for a SunSwift card.
SCSI devices are addressed as shown in the following table.
The addresses are set using the target address switches on the back of each SCSI device.
Before setting the target address, make sure that the power is off on the SCSI devices.
SCSI
Connector
UniPack Disk
Drive 1
(optional)
UniPack Disk
Drive 2
(optional)
UniPack Disk
Drive 3
(optional)
UniPack Disk
Drive 4
(optional)
UniPack
Tape Drive 1
(required)
UniPack
Tape Drive 2
(optional)
W
W
W
WW W
W
A
W
W
W
68-68 68-68
68-68
68-68
68-68
W = 68-68 pin SCSI cable
A = Auto-terminated
W
68-68
W
scsicble_swift.cdr
Device Address
Disk drive 1 0
Disk drive 2 1
Disk drive 3 2
Disk drive 4 3
Tape drive 1 4
Tape drive 2 5
!
Important:
!
Important:
Important: Do not use a target address
greater than 5.
Press this side to increase
the address number.
Press this side to decrease
the address number.
+
2
scsiidsw.cdr