Setting the remote console modem options
Issue 3.3 February 2003 53
Setting the options
To set the options on the Comsphere 3910, use the following procedures.
Configuring Factory/Async_Dial
1. Press F2 to select “Configure.”
“Ld EditArea frm” is displayed.
2. Press the Right Arrow four times.
“Factory” is displayed.
3. Press F1 to select “Factory.”
“Ld Fact Preset:” is displayed.
4. Press Right Arrow four times.
5. Press F1 to select “UNIX_Dial.”
6. Press F3 to select “Save.”
“Sav EditArea to” is displayed.
7. Press F1 to save to “Active(Saved).”
Since you are changing the active area to a new set of options (that is,
“Factory/Async_Dial”), the modem automatically performs another Power-On-Self-Test
(POST). Since the new options match the way the modem is connected, the ALRM
LED does not turn red. “Idle: 19.2” and “Status Configure” are displayed. To return to
the top-level menu, press the Double Up Arrow.
Setting the data rate
1. Press F2 to select “Configure.”
“Ld EditArea frm” is displayed.
2. Press the Right Arrow once.
“Active(Saved)” is displayed.
3. Press F1.
“Choose Function” is displayed.
4. Press F1 to select “Edit.”
“Edit StrapGroup” is displayed.
5. Press F1 to select “DTE_Interface.”
“Async/Sync Mode” is displayed.
6. Press F1 to select “Nxt.”
“Async DTE Rate” is displayed.